Manufacturers

GOS-6103C 100MHz Oscilloscope w/ Counter

GOS-6103C 100MHz Oscilloscope w/ Counter

* SMD Technology, High Stability and Reliability

* 100 MHz, Dual Channel, Delayed Sweep
* Built-in 6 Digit Universal Counter
* 10 Sets Memory for Front Panel Setting Save & Recall
* Time Base Auto-range
* Cursor Readout with 7 Measurements
* Panel Setup Lock of Digital-Control Functions
* Buzzer Alarm
* LED Indicators
* TV Synchronization
* Trigger Signal Output
* Z-Axis Modulation Input

More details


$1,255.00

8 other products in the same category:


CRT Type 6-inch rectangular type with internal graticule
0%, 10%, 90% and 100% markers. 8 x 10 DIV (1 DIV=1 cm)
Phosphor P31
Accelerating Potential 16 kV approx
Illumination Continuously adjustable
Z-Axis Input Coupling: DC
Sensitivity: 5V or more
Maximum Input Voltage: 30V (DC+AC peak) at 1kHz or less
Bandwidth: DC ~ 5MHz
Vertical System Sensitivity 2mV ~ 5V / DIV,11 step in 1-2-5 sequence
Sensitivity Accuracy ≤3% (5 DIV at the center of display)
Vernier Vertical Sensitivity Continuously variable to 1 / 2.5 or less panel-indicate value
Bandwidth (-3dB) DC ~ 100MHz (2mV/DIV : DC ~ 20MHz)
Rise Time 3.5nS (2mV/DIV : 17.5 nS)
Signal Delay Leading edge can be monitored
Max. Input Voltage 400V (DC+AC peak) at 1kHz or less
Input Coupling AC, DC, GND
Input Impedance 1MΩ±2% // approx. 25pF
Vertical Mode CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 INV
Bandwidth Limited 20MHz
Common-Mode Rejection Ratio 50 :1 or better at 50kHz
Dynamic Range 8 div at 100MHz
Horizontal System Horizontal Modes MAIN (A), ALT, DELAY (B)
A (main) Sweep Time 50nS ~ 0.5S / DIV, continuously variable (UNCAL)
B (delay) Sweep Time 50nS ~ 50mS / DIV
Accuracy ±3% (±5% at X10 MAG)
Sweep Magnification X10 (maximum sweep time 5nS / DIV)
Hold Off Time Variable
Delay Time 1µS ~ 5S
Delay Jitter Better than 1:20000
Alternate Separation Variable
Trigger Trigger Modes AUTO, NORM, TV
Trigger Source CH1, CH2, LINE, EXT
Trigger Coupling AC, DC, HFR, LFR
Trigger Slope "+" or "-" polarity or TV sync polarity
Trigger Sensitivity

Mode

Frequency

INT

EXT

AUTO

10Hz~20MHz

0.35 DIV

50 mV

20MHz~100MHz

1.5 DIV

150 mV

NORM

DC~20MHz

0.35 DIV

50 mV

20MHz~100MHz

1.5 DIV

150 mV

TV

sync signal

1 DIV

200 mVpp

TV Sync TV-V, TV-H
Max. External Input Voltage 400V (DC+AC peak) at 1kHz
External Input Impedance 1MΩ±5%, // approx. 25pF
X-Y Operation Mode X-axis: selectable CH1, CH2, EXT
Y-axis: selectable CH1, CH2, CH1 and CH2
Sensitivity Accuracy 2mV ~ 5V/DIV ±3%
EXT: 0.1V/DIV ±5%
X-axis Bandwidth DC ~ 500kHz (-3dB)
Phase Error 3º or less from DC ~ 50kHz
Output Signal Trigger Signal Output Voltage: approx. 25mV/DIV into 50Ω
Frequency response: DC ~ 10MHz
Calibrator Output 1kHz Squarewave, 2Vpp±2%
Cursor Readout Function Cursor Measurement Function ΔV, ΔV%, ΔVdB, ΔT, 1/ΔT, ΔT%, Δθ
Cursor Resolution 1 / 100 DIV
Effective Cursor Range Vertical: ±3DIV
Horizontal: ±4DIV
Panel Setting Display Vertical: V/DIV(CH1,CH2), UNCAL, ALT/CHOP/ADD, INV, probe factor, AC/DC/GND
Horizontal: S / DIV(MTB,DTB), UNCAL, X10MAG, delay time, HO
Trigger: source, coupling, slope, level, TV-V, TV-H
Others: X-Y, lock, save/recall MEM 0-9
Auto Measurement Function (GOS-6103C) Parameter Function FREQ, PERIOD, ±WIDTH, ±DUTY ( + or - polarity selected by trigger slope)
Display Digits Max. 6-digits, decimal
Frequency Range 50Hz - 100MHz
Accuracy 1kHz - 100MHz: ±0.01%
50Hz - 1kHz: ±0.05%
Measuring Sensitivity >2 div (Measuring source selected from CH1 and CH2 as synchronous signal sources)
Special Function TIME/DIV Auto Range Provided
Panel Setting Save & Recall 10 sets
Panel Setups Lock Provided
Power Source AC 100V / 120V / 230V±10%, 50 / 60Hz
Accessories Power cord, Instruction manual, Probes(10:1/1:1)
Size 12.2"W X 5.9"H X 17.9"D
Weight 19.8 lbs.