| Voltage
|
Range |
5V,
10V, 20V, 40V, 80V, 160V, 320V, 640V (total 8 ranges by
auto-range or manual) |
| Measurement
Type |
True
rms |
| Input
Resistance |
≥1MΩ |
Max.
Input Voltage |
1000V
(peak), 700V (rms) |
| PT
Ratio Setting |
1 ~
9999 |
Accuracy
(at 23°C±5°C, Sinewave) |
±0.1% of reading
±0.1% of range |
| Current
|
Range |
160mA,
320mA, 640mA, 1.280A, 2.560A, 5.120A, 10.24A, 20.48A (total 8
ranges by auto-range or manual) |
| Measurement
Type |
True
rms |
| Input
Resistance |
0.01Ω |
Max.
Input Current |
30A
(peak), 20A (rms) |
| CT
Ratio Setting |
1 ~
9999 |
Accuracy
(at 23°C±5°C, Sinewave) |
±0.1% of reading
±0.1% of range |
| Watt |
Measurement
Range |
0.32mW
~13.10kW |
| Measurement
Type |
True
rms |
Accuracy
(at 23°C±5°C, Sinewave) |
±0.2% of reading
±0.2% of range |
| Power
Factor |
Range |
0.001
~ 1.000 |
| Computation |
W / (V
x A) = Power Factor (PF) |
| Frequency |
Measurement
Range |
40Hz ~
400Hz |
Accuracy
(at 23°C±5°C) |
±0.2% of reading |
| Display |
4
digits 0.56" LED and 2 sets of 4 digits 0.4" LED |
| Minimum
Input |
2% of
reading |
| Response
Time |
2
cycles/sec |
| Overload
Indicating |
"
O.L " |
| Power
Source |
AC 86
~ 265V, 50/60Hz |
| Accessories |
Instruction
manual, Power cord
Option: RS-232
or RS-485 with disk |
| Size |
9.9"W X 3.6"H X 11.5"D |
| Weight |
3.5 lbs. |
|