| Model |
GDS-820
$816.00 |
GDS-820S
$985.50 |
GDS-820C
$1165.50 |
GDS-840S
$1308.00 |
GDS-840C
$1705.50 |
| Display
System |
Display Device |
Mono (320*240)
5.7" LCD |
Color (320*240)
5.7" LCD |
Mono (320*240)
5.7" LCD |
Color (320*240)
5.7" LCD |
| Display Contrast |
Adjustable |
| Waveform Display Graticule |
8 x 10 divisions
(8 x 12 div, when menu off) |
| Display Mode |
Dot, Vector, Accumulate |
| Vertical System
|
Bandwidth (-3dB) |
DC~150MHz |
DC~250MHz |
| Channels |
2 |
| Resolution |
8 bit |
| Sensitivity |
2mV/DIV
~ 5V/DIV |
| Accuracy |
±3% |
| Rise Time |
<2.3ns |
<1.4ns |
| Input Coupling |
AC, DC, GND |
| Input Impedance |
1MΩ ± 2%, ~22pF |
| Polarity |
Positive&
Negative |
| Maximum Voltage Between Signal and Common at input
BNC |
300V (DC +
AC peak), CAT II |
| Waveform Signal Process |
CH1-CH2, CH1+CH2,
FFT |
| Offset Range |
2mV/div ~ 50mV/div: ±0.5V
100mV/div
~ 500mV/div: ±5V
1V/div ~ 5V/div: ±50V |
| Bandwidth Limit |
20MHz (-3dB) |
| Horizontal System
|
Range |
1nS/DIV ~10S
/ DIV
Roll: 250mS/DIV ~ 10S/DIV (1-2-5 increments) |
| Modes |
MAIN, WINDOW,
WINDOW ZOOM, ROLL, X-Y |
| Accuracy |
±0.01% |
| Delay Range |
Pre-trigger: 20
DIV
Post-trigger: 1000 DIV |
| Signal Acquisition
System |
Real-time Sample Rate |
100MSa/s maximum on each channel |
| Equivalent Sample Rate |
25GSa/s maximum on each channel |
| Record Length |
125k / CH |
| Peak Detection |
10nS (500nS/DIV
~ 10S/DIV) |
| Acquisition Mode |
Sample, Peak Detect,
Average |
| Average |
2, 4, 8, 16,
32, 64, 128, 256 |
| Trigger System |
Source |
CH1, CH2,
LINE, EXT |
| Modes |
AUTO-LEVEL,
AUTO, NORMAL, SINGLE, TV, TIME DELAY, /EVENT DELAY, EDGE, PULSE
WIDTH |
| Coupling |
AC, DC, LF
rej, HF rej, Noise rej |
| Sensitivity |
DC
~ 25MHz: 0.35 DIV or 3.5mV
25MHz ~ 100MHz: 1.5 DIV or 15mV |
DC
~ 25MHz: 0.35 DIV or 3.5mV
25MHz ~ 250MHz: 1.5 DIV or 10mV |
| External Trigger |
Range |
±15V |
| Sensitivity |
DC
~ 30MHz: 50mV
30MHz ~ 100MHz: 100mV |
DC
~ 30MHz: 50mV
30MHz ~ 100MHz: 100mV
100MHz ~ 250MHz: 150mV |
| Input Impedance |
1MΩ ± 2%, ~22pF |
| Maximum Input |
300V (DC + AC peak), CAT II |
| X-Y Mode |
X-Axis Input / Y-Axis Input |
Channel 1 (CH1) / Channel 2 (CH2) |
| Phase Shift |
±3°
at 100kHz |
| Cursor &
Measurement |
Automated Voltage Measurement |
Vhi, Vlo, Vmax,
Vmin, Vpp, Vavg, Vrms, Vamp |
| Automated Time Measurement |
Rise Time,
Fall Time, Duty Cycle, Frequency, Period, Positive Width, Negative
Width |
| Cursor Measurement |
Voltage difference
between cursors (ΔV)
time difference between cursors (ΔT)
Frequency difference between cursors (1/ΔT) |
| Frequency Counter
|
Readout Resolution |
6 digits |
| Range |
AC Coupled, 10Hz
minimum to rated bandwidth |
| Signal Source |
All available trigger
source except the Pulse Width & Video Trigger mode |
| Control Panel Functions |
Autoset |
"Autoset"
adjust vertical (volt/DIV), horizontal (sec/DIV), and trigger
level automatically |
| Save/Recall |
Up to 15 sets
of measurement conditions can be saved and recalled |
| Waveform Trace Save/Recall |
2 sets of
waveform can be saved and recalled |
| Interface |
USB Interface |
N/A |
Standard |
| RS-232 Interface |
| Printer
port |
| Go-No Go Output |
| GPIB Interface |
Optional |
| Power Source |
Line Voltage Range |
100V ~ 240V
AC, automatic selection |
| Line Frequency |
48Hz ~ 63Hz |
| Power Consumption |
85Watts, 95VA
maximum, with fan |
| Accessories |
Power cord,
Instruction manual,
GDS-820 Series: GTP-150A Probes(10:1/1:1) x 2
GDS-840 Series: GTP-250A Probes(10:1/1:1) x 2
|
| Dimensions |
10.00"W
X 5.59"H X 12.20"D |
| Weight |
9.04 lbs |