| DC Voltage |
500mV, 5V, 50V, 500V, 1200V ±(0.02% +
2 digits) |
| AC Voltage True
RMS (AC or AC + DC True RMS) |
| 500mV ~ 1000V |
20Hz ~ 45Hz: ±(1% + 10 digits)
45Hz ~ 2kHz: ±(0.3% + 30 digits)
2kHz ~ 10kHz: ±(0.4% + 50 digits) |
| 500mV ~ 500V |
10kHz ~ 20kHz: ±(0.5% + 50 digits) |
| 500mV ~ 50V |
20kHz ~ 50kHz: ±(2% + 20 digits)
50kHz ~ 100kHz: ±(5% + 50 digits) |
|
| Input Impedance |
10 MΩ |
| DC Current |
500µA, 5mA, 50mA, 500mA: ±(0.05% +
3
digits)
2A, 20A: ±(0.2% + 5
digits) |
| AC Current True
RMS (AC or AC + DC True RMS) |
| 500µA, 5mA, 50mA, 500mA |
45Hz ~ 2kHz: ±(0.5%
+ 15 digits)
2kHz ~ 10kHz: ±(1% +
15 digits)
10kHz ~ 20kHz: ±(2% +
15 digits) |
| 2A, 20A |
45Hz ~ 2kHz: ±(0.5%
+ 15 digits) |
|
| Resistance |
500Ω: ±(0.1% + 4 digits)
5kΩ,
50kΩ, 500kΩ: ±(0.1% + 2 digits)
5MΩ: ±(0.2% + 2 digits)
20MΩ: ±(0.3% + 2 digits) |
| Diode Test |
The one ranges can check the forward
voltage of diode. Maximum forward voltage 1.5V. Open voltage 2.5V. |
| Capacitance |
5nF, 50nF, 500nF, 5µF, 50µF:
±(2% +
4 digits) |
Frequency
Input Level (Sine Wave) |
| mV range |
10Hz ~ 50kHz: >120mV
50k ~ 150kHz: >200mV |
| 5V~50V range |
10Hz ~ 200kHz: >1V |
| 500V range |
20Hz ~ 1kHz: >12V |
|
| Continuity
Beeper |
<5Ω |
| NMRR |
> 60dB |
| CMRR |
> 90dB |
| Operating Mode |
Auto Range / Manual |
| Display |
Dual Display 0.4", 0.5", 7
segment LED display |
| Power Source |
AC 100V / 120V / 220V / 230V ±10%, 50/60Hz |
| Accessories |
Instruction manual, Power cord,
Programming manual, Test
lead GTL-117 |
| Size |
9.9" X 3.6" X 11.5" |
| Weight |
4.1 lbs. |