* 3½ Digit, 1.2% basic
accuracy
* 9 Functions, 24 Ranges
* 100kHz Frequency
Counter
* 3 phase indicator
* Temperature -4° to
752° F, -20° to 400° C
* Capacitance 20,000µF
This multimeter is designed for electrical worker.
The frequency measurement can check the generator up to 500V. 3 phase RST can detect the
phase rotation while capacitance measurement with 20,000µF range can check large size
starter capacitor. It also features temperature measurement. Comes with temperature probe,
test leads, battery, spare fuse and operator's manual. Rubber holster with tilt-stand is
optional $5.00. |
| DCV |
2.000V, 20V, 200V, 600V(1.2%+1dgt) |
| ACV |
200.0V, 600V(2.0%+4dgts) |
| Resistance |
200.0Ω, 2k, 20k, 200k,
2000kΩ(1.0%+4dgts)
20MΩ(2.0%+4dgts), 200M, 2000MΩ(5.0%+10dgts)
|
| Capacitance |
20.00µF, 200µF, 2000µF, 20mF (4.0%+10dgts) |
| Frequency Counter |
10Hz to 100kHz (0.5%+2dgts) 2V RMS min. |
| Phase Indicator |
3 phase, 45-450Hz |
| Temperature |
- 20 to 400°C(2.0%+2°C) - 4 to
752°F(2.0%+4°F) |
| Diode Test |
1.0mA, 3.0V |
| Continuity Beeper |
<100Ω |
| Input Impedance |
10MΩ |
| Overload Protection |
500V for R, freq., T, diode, continuity |
| Size |
5.28"
x 2.8" x 1.5" |
| Weight |
12.9 oz. |
| Power |
9V battery, 200hrs |
|