Ranges
|
0 to 0.12Ω
0 to 0.6Ω |
| Resolution
|
0.002Ω |
| Test Current
|
AC 3A to 32A
|
| Test Voltage
|
8 VAC max
|
| Accuracy
|
10% full scale 3A to 5A, 5%
full scale 5A to 32A
|
| Resistance
Meter
|
Indicate the testing
resistance and setting value of Fail and Subtraction |
| Switching
|
Zero-start operating switch
|
| Timer
|
1s, 10s, 1min,
10min
|
| Warning
|
When the test current variation is over 10%
of setting value
|
| Subtraction
|
The test line resistance can
be subtracted from the test value
|
| GO NO-GO set |
Beeps when the test value is over the setting value |
| Test Mode |
Normal: Test will be stopped when warning is
activated
Continue: Test will continue when warning is activated |
|
Remote Control |
Input high voltage range from 11V to 15V, low voltage range from 0 to 4V,
input low current range below 20mA |
| Test Frequency |
50/60 Hz |
| Output Signal |
TEST, GO, NO GO, WARNING, READY, MONITOR |
| Power |
120/240Vą10%, 50/60 Hz |
| Size |
16.9"W X 7"H X 20"D |
| Weight |
46.2 lbs. |
| Accessories |
test leads, manual |
|